Thanks to the principle of radio wave tissue lifting, based on the contact effect of high-frequency electric current for the purpose of controlled heating of the dermis and subcutaneous fat, a certain temperature regime is created that initiates the denaturation of collagen fibers and stimulates the synthetic activity of fibroblasts.
With the help of controlled inflammation in the dermis, the aesthetic effect of the procedure is created and the skin is restructured and rejuvenated.
The system combines the functions of vacuum and RF technology. Using different levels of vacuum exposure, the device can warm up different layers of the skin and increase the metabolic rate. Exposure to radio waves reduces the depth of wrinkles and significantly strengthens skin tone, and in combination with vacuum therapy, blood circulation improves, lymphatic drainage is stimulated and the volume of fat cells is reduced. Studies have shown that after the procedure the number of red blood cells and plasma fluid increases, which indicates increased blood circulation.
4 vacuum levels and 4 power levels allows you to individually select the optimal parameters for the most comfortable and effective procedure. The special ReFit protocol was created to solve the problems of loose and sagging skin that arise after liposuction procedures or with large and rapid weight loss.
The procedure is painless and does not require anesthesia or cooling, because if heat is generated in only one part of the dermis, it quickly dissipates. In contrast, when different layers of the dermis are heated, the heat takes longer to escape, so it takes longer to stimulate the cells.
RF - lifting or laser infrared thermolifting - how to figure out which is better?
Most modern hardware rejuvenation technologies are based on the effects of radio waves or lasers. All these techniques are called thermolifting and “work” in approximately the same way - they heat the skin layers, triggering the production of new collagen.
For a beginner, the sophisticated names of numerous procedures in this series sound the same. In fact, how can you figure out what the difference is between RF lifting and thermolifting using lasers? And what is better, infrared fractional thermolifting with the Palomar laser or Fraxel dermal optical thermolysis?
New technologies for preserving youth are so diverse that it is impossible to do without special education or “your own” cosmetologist.
Laser skin rejuvenation.
At Platinental we have collected almost all modern methods of non-surgical rejuvenation. We work closely with each one, we know their advantages and disadvantages, and we always draw up an individual treatment plan for our patients. After all, couperose skin at 35 and excess skin at 45 require a different approach.
Meanwhile, RF thermal lifting Reaction has a number of advantages, and they are significant.
Applicator for the procedure
Applicator for the procedure lifting | Applicator for body | Applicator for face | |
RF power | up to 125 J/cm³ | up to 50 W | up to 8.5 W |
RF mode 1 | 850 kHz | 850 kHz | 850 kHz |
RF mode 2 | 1.7 MHz | 1.7 MHz | 1.7 MHz |
RF mode 3 | 2.45 MHz | 2.45 MHz | 2.45 MHz |
RF mode 4 | 850 kHz, 1.7 MHz, 2.45 MHz | 850 kHz, 1.7 MHz, 2.45 MHz | 850 kHz, 1.7 MHz, 2.45 MHz |
Vacuum | absent | throbbing | throbbing |
Surface to be processed | 8 mm x 8 mm | 35 mm x 30 mm | 15 mm x 10 mm |
Weight | 17 kg (without wheelbase) 19 kg (weight of wheelbase) | ||
Dimensions | 40 cm (length) x 35 cm (width) x 45 cm (height) | ||
Electrical parameters | AC voltage 90-264; 50/60 Hz |
Reaction 5: the impact is deeper, the effect is more obvious
Most of these techniques work on the superficial layers of the skin. Reaction heats three layers at once, triggering collagen production at a deep level. The effect of the procedure increases over several months and then persists for a long time.
Second plus
deeper impact of Reaction: it is less traumatic for the surface layer of the skin.
This means that you will leave the session radiant and rejuvenated, and not red and swollen
.
Third plus
: CORE technology allows flexible control of exposure temperature. Which negates the possibility of adverse effects of radio wave thermolifting - for example, a continuous subcutaneous scar that occurs due to tissue overheating.
And finally, the fourth advantage
technology – exceptionally painless sensations of internal warmth during the procedure.
Expert comment:
Thermolifting “awakens” collagen, starting the process of natural restoration and rejuvenation of the skin.
And if you combine deep thermal lifting Reaction
, rejuvenation with Silhouette Lift threads and facial reinforcement Radiesse - in fact, this procedure
can become a safe and effective alternative to surgical lifting
.
The fundamental difference between the Reaction technique and, for example, fractional (point) lasers is that they work with the surface layer of the skin and only a little with the dermis itself. During the RF procedure, deep
thermolifting, affecting not only the dermis itself, but even the subcutaneous fatty tissue.
The laser evens out the relief, removes pigment, blurs scars, and RF, due to its deeper impact, also melts fat. Therefore, thermolifting of the body can be considered, perhaps, as one of the few analogues of liposuction.
To achieve a 3D effect, you can combine radio wave thermolifting of the face with other techniques. For example, with the same lasers that give the skin porcelain smoothness. Or use deep ultrasonic facial lifting for an intensive tightening.
Baltacheeva Elmira, dermatocosmetologist.
Review:
“I’m 45. I came to the clinic with the problem of an “apron” on my stomach. Platinental recommended me Reaction thermolifting. They showed “before” and “after” photos of those who had the procedure done.
What I saw inspired me, and I completed 6 sessions. The effect after the course was like losing weight. Only more durable. And the skin on my stomach became as elastic as my daughter’s.
Many thanks to Elmira Baltacheeva! She was able to show me that age is not a barrier to real beauty!
Inna N., Moscow
Carrying out procedures and contraindications to them
RF lifting using the Reaction device is carried out in short sessions of an average of 25 minutes. A pronounced effect appears after 2–10 sessions. The interval between sessions ranges from 10 days to 2 weeks. At the same time, the first visual positive results, which subsequently increase and stabilize, are noted after the first or second session. The RF lifting procedures themselves using the Reaction device are not only painless, but they do not even cause any discomfort and do not require a rehabilitation period.
The use of RF lifting with the Reaction device is contraindicated if you have:
- pregnancy or breastfeeding;
- electronic implant or pacemaker;
- connective tissue diseases of an autoimmune nature;
- malignant disease;
- herpetic disease (exposure to areas where a herpetic rash previously appeared should be excluded);
- taking Noaccutane (isotretinoin) for acne (before the expiration of 1 year);
- bleeding disorders;
- acute viral or bacterial infections;
- infectious skin diseases, inflammatory processes of the skin, chronic dermatoses, keloid scars in the area of intended exposure;
- uncompensated arterial hypertension, epilepsy, deep vein thrombosis;
- insulin-dependent diabetes mellitus and uncompensated thyroid function;
- tattooing or permanent makeup, previous cosmetic surgeries or surgical interventions for any diseases in the area of intended treatment.
Varieties of the method
Any RF lifting has a general principle - exposure to a wave in the radio frequency range. However, several options for thermolifting differ in intensity and distribution of radiation:
- Monopolar type. In this case, a so-called monopolar RF lifting device is used, which has one needle electrode. This option is considered somewhat outdated, but is still widely used. This lifting device provides fairly powerful radiation that heats a large area of skin to a temperature of 58-65 ºC. Taking into account the dispersion of radiation and its rigidity, monopolar lifting is not used for the face, but is used for large areas, in particular for the elimination of cellulite. The main advantage is the presence of a pronounced effect after the first session.
- Bipolar RF therapy involves the use of 2 directional electrodes. The wave is directed exactly to the right place without heating neighboring tissues. In general, the radiation with this technology is much softer, and heating is provided up to 44-46 ºC.
- Tripolar and polypolar type . This is an improved version of RF lifting devices, which use 5 or more needle-type electrodes that can be turned on in a certain sequence. In this case, optimal impact is ensured both in localization and duration. It is with the help of this method that thermal lifting of the face and other most sensitive areas is carried out.
But what mesothreads for thread lifting look like and why such a procedure is carried out is indicated here.
How is RF lifting done?
An RF lifting session is non-traumatic and absolutely painless. The original gel is applied to the cleaned surface, after which the treatment of problem areas is carried out along certain lines using special nozzles. In total, several maniples are used, which differ depending on the purposes and areas of their application. RF lifting is carried out in a course of 3-6 sessions. One operation takes from 30 minutes to 1.5 hours, depending on the area of the treated area. High frequency RF pulses stimulate the production of new collagen fibers. In turn, rarefied air improves microcirculation and metabolic processes. This highly effective tandem of technologies allows you to achieve the most desired results: restoring skin elasticity, modeling the silhouette, and renewing subcutaneous structures. The reaction to the procedure is a slight redness of the area. The lifting effect becomes noticeable after the first session and increases, firstly, due to the direct thermal RF effect on the tissue, and secondly, due to the launch of active processes of restructuring and recreation of the cellular structure of the skin.
Advantages of Viora V-20
- A comprehensive range of effective technologies and procedures
- Absolute safety and predictable results
- Compact dimensions - everything you need in a minimal office area
- Various sizes of head attachments to suit different areas
- Full control of operating parameters to solve each specific task
- Ability to work in delicate areas: neck, décolleté, hands, intimate area
- Painlessness and minimal recovery time
- Maximum economic efficiency
RF face lifting price
Impact area | Procedure time in min. | Price, rub.* |
Face, skin tightening | 40 | 6000 |
Eye area, wrinkle elimination | 40 | 3900 |
Eyelids with zygomatic area, elimination of wrinkles | 40 | 4700 |
Forehead, rejuvenation | 40 | 4500 |
Cheeks | 40 | 4500 |
Cheeks with chin | 40 | 4700 |
Around the mouth | 40 | 4500 |
Neck | 40 | 4500 |
Cleavage | 40 | 6000 |
Hands | 40 | 4500 |
Faces and necks | 60 | 8000 |
Neck and décolleté | 60 | 8000 |
Face, neck and décolleté | 80 | 11900 |
Application area:
- RF lifting (non-surgical skin tightening)
- Increased skin tone
- Changing the oval of the face
- Elimination of jowls
- Elimination of all types of wrinkles
- Skin smoothing
- Elimination of enlarged pores
- Scar removal
- Removing Stagnant Stains
- Getting rid of the “double chin”
- Getting rid of excess fat, sagging skin, sagging skin, “sides”
- Getting rid of cellulite, “orange peel”
- Modeling body contours, slimming (reducing by 1-2 sizes and tightening)
- Hand skin rejuvenation
- Removing acne spots
- Elimination of stretch marks after childbirth
Space technologies in the beauty industry
Cosmetology specialists have long been solving the important problem of loss of skin elasticity. In many people, due to rapid weight loss, the skin becomes thinner, sag, and loses its elasticity. This is partly due to various imbalances in the balance between the important substances elastin and collagen. This failure can cause stretch marks on the skin, the appearance of various folds, sagging - in general, the whole bouquet that every woman fears. Naturally, such a problem cannot in any way be left without a timely solution. After all, a woman’s beauty is most important! This is where radio electronics come to our aid in the form of the inherently unique radio frequency lifting device Reaction.
The Reaction Viora device is a high-tech radio frequency device developed by specialists from the Viora company, located in Israel. Everyone has long known that Israeli cosmetology is one of the most advanced, so the effectiveness of this device and the treatment method it performs is beyond any doubt.
The basic operating principle of the device uses the patented “CORETM” technological system. This technology has three main characteristics, according to which radio waves in cosmetology penetrate to different depths; there is also a hybrid fourth mode, which allows you to generate three different frequencies at once in a single pulse.